Description
- Lead free
- Armoured with galvanized steel wires (SWA) or aluminium wires (AWA)
- Aliphatic and aromatic hydrocarbons resistant.
Standards
International : IEC 60228; IEC 60332-3-22 Cat.ADescription
Applications
These power and control cables are used for electricity supply in low voltage installation system, in moist areas and where aliphatic and aromatic hydrocarbons may be present. They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plant...). Hypron® offers an alternative to conventional lead covered cable and is an environmental friendly solution.
Design
Conductor
- Solid plain copper: 1.5 to 4 mm²
- Stranded plain copper: 1.5 to 630 mm²
Insulation:
- Cross-linked polyethylene (XLPE)
Assembling (optional):
- Inner sheath acting as a filler with practically zero thickness
or
- Assembling polyester tape
Screen/sealing barrier:
- Tinned copper drain wire,
- Aluminium/polyethylene tape
Inner sheath:
- High density polyethylene (HDPE)
- Colour: black
Special sheath: (intermediate sheath)
- Polyamide
Armour:
- Galvanized steel wires (SWA)
or
- Aluminium wires (AWA) for 1 core cable
Outer sheath:
- Polyvinyl chloride (PVC)
Colour : black. Other colour on request.
Core identification
1 core: black
2x to 5G cores: according to HD 308 S2
Above 5 cores: black core printed with white number
Marking
NEXANS 279 XLPE/AL/HDPE/NC/AWA or SWA/PVC 0.6/1 kV Nber of cores and cross-section Cu IEC 60332-3-22(A) MM YYYY manufacturing number + meter marking
IEC 60502-1 (design guide-lines)
Characteristics
| Construction characteristics | |
|---|---|
| Conductor material | Plain copper |
| Type of conductor | Stranded, Class 2 |
| Insulation | XLPE (Cross-linked Polyethylene) |
| Intermediate sheath | Polyamide |
| Armour type | Galvanized steel wires |
| Outer sheath | PVC |
| With Green/Yellow core | No |
| Lead free | Yes |
| Dimensional characteristics | |
| Number of cores | 4 |
| Conductor cross-section | 50mm² |
| Conductor diameter | 8.11mm |
| Diameter over insulation | 10.1mm |
| Diameter over intermediate sheath | 28.3mm |
| Diameter over armour | 32.3mm |
| Minimum outer diameter | 37.3mm |
| Maximum outer diameter | 41.1mm |
| Approximate weight | 3510kg/km |
| Electrical characteristics | |
| Rated Voltage Uo/U (Um) | 0.6/1 kV |
| Mechanical characteristics | |
| Mechanical resistance to impacts | Good |
| Usage characteristics | |
| Fire retardant | IEC 60332-3-22 |
| Chemical resistance | Aliphatic and aromatic hydrocarbons resistant |
| Max. conductor temperature in service | 90°C |
| Operating temperature, range | -20 .. 60°C |
Docs and info
Related documents
Selling information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations
Cables with reduced neutral on request